{"id":7389,"date":"2019-03-16T21:42:26","date_gmt":"2019-03-16T12:42:26","guid":{"rendered":"https:\/\/advance-riko.com\/develop\/contract-analysis\/wettability\/"},"modified":"2024-12-25T13:55:22","modified_gmt":"2024-12-25T04:55:22","slug":"wettability","status":"publish","type":"page","link":"http:\/\/advance-riko.com\/en\/contract-analysis\/wettability\/","title":{"rendered":"wettability \/ contact angle analysis"},"content":{"rendered":"<p>Wettability and contact angle can be measured.<\/p>\n<div class=\"mt50 box-layout two-column\">\n<div class=\"box text\">The wettability of a liquid is how much it spreads over the surface of a particular solid, measured by the flatness of a droplet on the solid surface.<br \/>\nOne of the major methods, the static drop method is used to measure contact-angle of the droplet to the surface.<\/div>\n<figure class=\"box\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7393\" src=\"http:\/\/advance-riko.com\/develop\/wp-content\/uploads\/wettability01-en.gif\" alt=\"\" width=\"800\" height=\"440\" srcset=\"http:\/\/advance-riko.com\/develop\/wp-content\/uploads\/wettability01-en.gif 800w, http:\/\/advance-riko.com\/develop\/wp-content\/uploads\/wettability01-en-768x422.gif 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/div>\n<div class=\"mt50 box-layout two-column\">\n<figure class=\"box\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7395\" src=\"http:\/\/advance-riko.com\/develop\/wp-content\/uploads\/wettability02-en.gif\" alt=\"\" width=\"800\" height=\"600\" srcset=\"http:\/\/advance-riko.com\/develop\/wp-content\/uploads\/wettability02-en.gif 800w, http:\/\/advance-riko.com\/develop\/wp-content\/uploads\/wettability02-en-768x576.gif 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<div class=\"box text\">Features of extruded liquid drop method<\/p>\n<ol class=\"ol-design01\">\n<li>Fresh droplet can be used.<\/li>\n<li>Droplet size can be changed arbitrarily.<\/li>\n<li>Advancing \/Receding contact angles can be measured.<\/li>\n<\/ol>\n<\/div>\n<\/div>\n<h3 class=\"mt50 mb10\">static drop method<\/h3>\n<div class=\"table_scroll02\">\n<table class=\"table-design04\">\n<tbody>\n<tr>\n<th>temperature range<\/th>\n<th>atmosphere<\/th>\n<th>sample size, shape<\/th>\n<\/tr>\n<tr>\n<td>room temperature\u301c500\u2103<\/td>\n<td rowspan=\"2\">air<br \/>\ninnert gas<br \/>\n*Consult us about other types of gas.<\/td>\n<td rowspan=\"2\">substrate \u03c610\u339c\u00d7 thickness 2\u339c<\/td>\n<\/tr>\n<tr>\n<td>room temperature\u301c1200\u2103<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3 class=\"mt50 mb10\">extruded liquid drop method<\/h3>\n<div class=\"table_scroll02\">\n<table class=\"table-design04\">\n<tbody>\n<tr>\n<th>temperature range<\/th>\n<th>atmosphere<\/th>\n<th style=\"width: 230.55px;\">sample size, shape<\/th>\n<\/tr>\n<tr>\n<td>room temperature\u301c500\u2103<\/td>\n<td rowspan=\"2\">air<br \/>\ninnert gas<br \/>\n*Consult us about other types of gas.<\/td>\n<td style=\"width: 230.55px;\" rowspan=\"2\">Consult us about samples.<\/td>\n<\/tr>\n<tr>\n<td>room temperature\u301c1200\u2103<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h3 class=\"mt50 mb10\">contact angle measurement<\/h3>\n<div class=\"table_scroll02\">\n<table class=\"table-design04\">\n<tbody>\n<tr>\n<th>temperature range<\/th>\n<th>atmosphere<\/th>\n<th>sample size, shape<\/th>\n<\/tr>\n<tr>\n<td>\u30fc<\/td>\n<td>\u30fc<\/td>\n<td>\u30fc<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"mt20 text-right\">suitable for this measurement\uff1a<a href=\"\/en\/products\/wet-1200\/\">Hight Temperature Wettability Evaluation System by Contact Angle at the Solid-Liquid Interface WET-1200<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Wettability and contact angle can be measured. The wettability of a liquid is how much it spreads over the surface of a particular solid, measured by the flatness of a droplet on the solid surface. One of the major methods, the static drop method is used to measure contact-angle of the droplet to the surface. Features of extruded liquid drop method Fresh droplet can be used. Droplet size can be changed arbitrarily. Advancing \/Receding contact angles can be measured. static drop method temperature range atmosphere sample size, shape room temperature\u301c500\u2103 air innert gas *Consult us about other types of gas. substrate \u03c610\u339c\u00d7 thickness 2\u339c room temperature\u301c1200\u2103 extruded liquid drop method [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":6748,"menu_order":12,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-7389","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"http:\/\/advance-riko.com\/en\/wp-json\/wp\/v2\/pages\/7389","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/advance-riko.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/advance-riko.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/advance-riko.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/advance-riko.com\/en\/wp-json\/wp\/v2\/comments?post=7389"}],"version-history":[{"count":0,"href":"http:\/\/advance-riko.com\/en\/wp-json\/wp\/v2\/pages\/7389\/revisions"}],"up":[{"embeddable":true,"href":"http:\/\/advance-riko.com\/en\/wp-json\/wp\/v2\/pages\/6748"}],"wp:attachment":[{"href":"http:\/\/advance-riko.com\/en\/wp-json\/wp\/v2\/media?parent=7389"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}