{"id":15370,"date":"2019-03-17T20:01:47","date_gmt":"2019-03-17T11:01:47","guid":{"rendered":"https:\/\/advance-riko.com\/develop\/contract-analysis\/list\/"},"modified":"2026-08-08T12:22:19","modified_gmt":"2026-08-08T03:22:19","slug":"contract-analysis","status":"publish","type":"page","link":"http:\/\/advance-riko.com\/zh-hans\/contract-analysis\/","title":{"rendered":"\u59d4\u6258\u5206\u6790\u9879\u76ee\u6e05\u5355"},"content":{"rendered":"<p>\u4e3a\u4e86\u652f\u6301\u65b0\u578b\u6750\u6599\u53ca\u529f\u80fd\u6027\u6750\u6599\u7684\u5f00\u53d1\uff0c\u4ee5\u53ca\u5bf9\u5176\u70ed\u7279\u6027\/\u70ed\u7269\u6027\u7684\u8bc4\u4ef7\u7814\u7a76\uff0cADVANCE RIKO \u63d0\u4f9b\u4e13\u4e1a\u7684\u59d4\u6258\u5206\u6790\u670d\u52a1\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-6478\" src=\"\/develop\/wp-content\/uploads\/laboratory.jpg\" alt=\"\" width=\"400\" height=\"270\" srcset=\"http:\/\/advance-riko.com\/develop\/wp-content\/uploads\/laboratory.jpg 800w, http:\/\/advance-riko.com\/develop\/wp-content\/uploads\/laboratory-768x518.jpg 768w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/>\u9488\u5bf9\u5f53\u524d\u5907\u53d7\u5173\u6ce8\u7684\u70ed\u7535\u6750\u6599\u8bc4\u4ef7\uff0c\u9664\u63d0\u4f9b\u5df2\u6210\u4e3a\u5168\u7403\u884c\u4e1a\u4e8b\u5b9e\u6807\u51c6\uff08De Facto Standard\uff09\u7684 ZEM-3 \u7cfb\u5217\u6d4b\u8bd5\u5916\uff0c\u8fd8\u53ef\u5229\u7528\u626b\u63cf\u5f0f\u70ed\u63a2\u9488\u6cd5\uff08STPM\uff09\u5bf9\u70ed\u7535\u6750\u6599\u7684 Seebeck \u7cfb\u6570\u9762\u5185\u5206\u5e03\u8fdb\u884c\u8bc4\u4ef7\u3002<\/p>\n<p>\u5728\u70ed\u5bfc\u7387\u6d4b\u8bd5\u65b9\u9762\uff0c\u53ef\u5bf9\u5e94\u4ece\u8584\u819c\u5230\u5757\u4f53\u3001\u4ece\u91d1\u5c5e\u5230\u6709\u673a\u6750\u6599\u7b49\u591a\u79cd\u6750\u6599\u7684\u6d4b\u8bd5\u9700\u6c42\u3002\u6b64\u5916\uff0c\u8fd8\u53ef\u63d0\u4f9b\u70ed\u81a8\u80c0\u7cfb\u6570\u6d4b\u91cf\u4ee5\u53ca\u7ea2\u5916\u52a0\u70ed\u8bc4\u4ef7\u8bd5\u9a8c\u7b49\u670d\u52a1\u3002<\/p>\n<p>\u6b64\u5916\uff0c\u7535\u5f27\u7b49\u79bb\u5b50\u4f53\u7eb3\u7c73\u9897\u7c92\u5de5\u827a\u975e\u5e38\u9002\u7528\u4e8e\u71c3\u6599\u7535\u6c60\u50ac\u5316\u5242\u3001\u5149\u50ac\u5316\u5242\u7b49\u9886\u57df\u7684\u7814\u53d1\u3002ADVANCE RIKO \u8fd8\u53ef\u5229\u7528\u7535\u5f27\u7b49\u79bb\u5b50\u4f53\u6280\u672f\uff0c\u4e3a\u5404\u79cd\u6750\u6599\u63d0\u4f9b\u7eb3\u7c73\u9897\u7c92\u6210\u819c\u8bd5\u6837\u5236\u5907\u670d\u52a1\uff0c\u652f\u6301\u590d\u5408\u7eb3\u7c73\u6750\u6599\u7684\u5f00\u53d1\uff0c\u4ee5\u63d0\u5347\u50ac\u5316\u6027\u80fd\u3002<\/p>\n<h2 class=\"mt50\">thermal analysis \/ thermophysical property evaluation<\/h2>\n<table class=\"table-design02 f-size14\">\n<thead>\n<tr>\n<th colspan=\"2\"><a href=\"https:\/\/advance-riko.com\/en\/contract-analysis\/thermoelectric-measurement\/\">thermoelectric evaluation<\/a><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th class=\"w30p\">Seebeck coefficient<\/th>\n<td>It can be calculated by temperature difference between both ends of a samle which has temperature gradient in itself after being heated on its both ends with temperature gradient up to 50\u2103 and electromotive force in response to the temperature difference of the sample.<\/td>\n<\/tr>\n<tr>\n<th>thermoelectric conversion efficiency<\/th>\n<td>Apply temperature difference to thermoelectric module and then evaluate its power generation efficiency from current dependency on power generation amount and heat flow.<\/td>\n<\/tr>\n<\/tbody>\n<thead>\n<tr>\n<th colspan=\"2\"><a href=\"https:\/\/advance-riko.com\/en\/contract-analysis\/thermal-conductivity-measurement\/\">thermal conductivity\/thermal diffusivity<\/a><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th>laser flash method<\/th>\n<td>Laser flash method is used to measure thermal diffusivity of a sample from temperature rise on the backside of the sample after laser-pulse-heating the front side of the sample.<\/td>\n<\/tr>\n<tr>\n<th>Xe flash method<\/th>\n<td>Xe flash method is used to measure thermal diffusivity of a sample from temperture rise on the backside of the sample after xenon-pulse-heating the front side of the sample.<\/td>\n<\/tr>\n<tr>\n<th>scanning laser heating AC method<\/th>\n<td>Scanning laser heating AC method \/ Apply a band of laser to the surface of a thin film sample periodically and then evaluate the thermal diffusivity of the sample in-plane direction.<\/td>\n<\/tr>\n<tr>\n<th>periodic heating method<\/th>\n<td>Apply periodic heating to a sample and then evaluate the thermal diffusivity of the sample from the temperature behaviour caused by periodic temperature change.<\/td>\n<\/tr>\n<tr>\n<th>steady method<\/th>\n<td>keep steady temperature gradient on a sample by applying higher temperature at one end of the sample and lower temperature at the other end and then calculate thermal conductivity after measuring the temperature.<\/td>\n<\/tr>\n<tr>\n<th>2 omega method<\/th>\n<td>By detecting thermal amplitude with thermo-reflectance method, thermal conductivity of an insulating film on the substrate can be measured in thickness direction.<\/td>\n<\/tr>\n<tr>\n<th>scanning thermal probe<\/th>\n<td>Seebeck coefficient and thermal conductivity (in-plane direction ) can be measured.<\/td>\n<\/tr>\n<thead>\n<tr>\n<th colspan=\"2\"><a href=\"https:\/\/advance-riko.com\/en\/contract-analysis\/differential-thermal-analysis\/\">differential thermal analysis\/differential thermogravimetric analysis<\/a><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th>differential thermal analysis\/differential thermogravimetric analysis<\/th>\n<td>While a sample and its reference substance are going through an identical thermal cycle, mass difference and temperature difference of both materials are measured continuously to observe changes both physical and chemical of them.<\/td>\n<\/tr>\n<\/tbody>\n<thead>\n<tr>\n<th colspan=\"2\"><a href=\"https:\/\/advance-riko.com\/en\/contract-analysis\/thermal-expansion-measurement\/\">thermal expansion measurement<\/a><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th>pushrod displacement detector<\/th>\n<td>Change of a sample after heated is passed through a quartz glass detector to a differential transformer, and then a sensor inside the transformer moves to show output fluctuation, which is calculated as expansion \/ contraction of the sample.<\/td>\n<\/tr>\n<tr>\n<th>laser interferometry<\/th>\n<td>A method to quantify thermal expansion by measuring expansion change of a sample caused by temperature change, which is regarded as amount of stripe\u2019s movement by two beam interference. (double optical path Michelson interferometer)<\/td>\n<\/tr>\n<thead>\n<tr>\n<th colspan=\"2\"><a href=\"https:\/\/advance-riko.com\/en\/contract-analysis\/saturated-vapor-pressure-measurement\/\">saturated vapor pressure measuerement<\/a><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th><\/th>\n<td>When a material is heated in a vacuum at a steady heating rate, the weight of the material decreases. With the weight loss caused by vaporing and the change of temperatuure, thermogravimetric curve is obtained and then able to calculate saturated vapor pressure and evaporation rate.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 class=\"mt50\">gas analysis<\/h2>\n<table class=\"table-design02 f-size14\">\n<thead>\n<tr>\n<th colspan=\"2\"><a href=\"https:\/\/advance-riko.com\/en\/contract-analysis\/thermoelectric-measurement\/\">thermal desorption<\/a><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th class=\"w30p\">thermal desorption<\/th>\n<td>The cold wall structure allows gas analysis to be done under the environment with high temperature and little gas emission.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 class=\"mt50\">heating test<\/h2>\n<table class=\"table-design02 f-size14\">\n<thead>\n<tr>\n<th colspan=\"2\"><a href=\"https:\/\/advance-riko.com\/en\/contract-analysis\/thermoelectric-measurement\/\">heat treatment<\/a><\/th>\n<\/tr>\n<tr>\n<td>Annealing and gas-quenching of materials ae available under various kinds of atmosphere.<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\"><a href=\"https:\/\/advance-riko.com\/en\/contract-analysis\/thermoelectric-measurement\/\">wettability \/ contact angle<\/a><\/th>\n<\/tr>\n<tr>\n<td>Wettability and contact angle can be measured.<\/td>\n<\/tr>\n<tr>\n<th colspan=\"2\"><a href=\"https:\/\/advance-riko.com\/en\/contract-analysis\/thermoelectric-measurement\/\">high-temperature observation<\/a><\/th>\n<\/tr>\n<tr>\n<td>Various conditions of materials can be observed like crystal transformation, deposition, solidification, molten state.<\/td>\n<\/tr>\n<\/thead>\n<\/table>\n<h2 class=\"mt50\">microvial growth activity<\/h2>\n<table class=\"table-design02 f-size14\">\n<thead>\n<tr>\n<th colspan=\"2\"><a href=\"https:\/\/advance-riko.com\/en\/contract-analysis\/thermoelectric-measurement\/\">microbial activity measurement<\/a><\/th>\n<\/tr>\n<tr>\n<td>Microbial activity can be evaluated from amount of heat generated by microbials which are placed inside a container equipped with heat detector.<\/td>\n<\/tr>\n<\/thead>\n<\/table>\n<h2 class=\"mt50\">deposition test<\/h2>\n<table class=\"table-design02 f-size14\">\n<thead>\n<tr>\n<th colspan=\"2\"><a href=\"https:\/\/advance-riko.com\/en\/contract-analysis\/thermoelectric-measurement\/\">thin film coating\/nano particle coating<\/a><\/th>\n<\/tr>\n<tr>\n<td>Metal ions are created and then ultra thin films and nanoparticles are formed by pulse arc-deposition of the metal ions. The films\u2019 flatness and particles\u2019 finecess are satisfactory compared to those created by other methods.<\/td>\n<\/tr>\n<\/thead>\n<\/table>\n<p class=\"mt20\">Custom-made sampling is also available. Please feel free to contact us.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u4e3a\u4e86\u652f\u6301\u65b0\u578b\u6750\u6599\u53ca\u529f\u80fd\u6027\u6750\u6599\u7684\u5f00\u53d1\uff0c\u4ee5\u53ca\u5bf9\u5176\u70ed\u7279\u6027\/\u70ed\u7269\u6027\u7684\u8bc4\u4ef7\u7814\u7a76\uff0cADVANCE RIKO \u63d0\u4f9b\u4e13\u4e1a\u7684\u59d4\u6258\u5206\u6790\u670d\u52a1\u3002 \u9488\u5bf9\u5f53\u524d\u5907\u53d7\u5173\u6ce8\u7684\u70ed\u7535\u6750\u6599\u8bc4\u4ef7\uff0c\u9664\u63d0\u4f9b\u5df2\u6210\u4e3a\u5168\u7403\u884c\u4e1a\u4e8b\u5b9e\u6807\u51c6\uff08De Facto Standard\uff09 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":3,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-15370","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"http:\/\/advance-riko.com\/zh-hans\/wp-json\/wp\/v2\/pages\/15370","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/advance-riko.com\/zh-hans\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/advance-riko.com\/zh-hans\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/advance-riko.com\/zh-hans\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/advance-riko.com\/zh-hans\/wp-json\/wp\/v2\/comments?post=15370"}],"version-history":[{"count":2,"href":"http:\/\/advance-riko.com\/zh-hans\/wp-json\/wp\/v2\/pages\/15370\/revisions"}],"predecessor-version":[{"id":37669,"href":"http:\/\/advance-riko.com\/zh-hans\/wp-json\/wp\/v2\/pages\/15370\/revisions\/37669"}],"wp:attachment":[{"href":"http:\/\/advance-riko.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=15370"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}