Power Generation Efficiency Characteristics Evaluation System PEM-2

Property evaluations of thermoelectric generator modules

By applying a maximum 500°C temperature difference across a thermoelectric generator module, this system finds the thermoelectric conversion rate η by finding the power that is generated P when a one-dimensional heat flow Q is passed through the module.

Applications

  • Generation efficiency measurements of thermoelectric generator modules
  • Lifespan testing of modules by thermal cycle testing

Features

  • Uses an Infrared Gold Image Furnace with excellent temperature controllability to allow rapid module performance evaluations and endurance testing.
  • Capable of applying a maximum 500°C temperature difference across the top and bottom surface of the module.
  • Capable of measuring the amount of heat passed through the module.
  • Stably maintains the thermal resistance of the contact surface during heating with the air cylinder mechanism.
  • Measurement behavior can be configured with only software settings by temperature stability judgments, automatic variation of the load on the thermoelectric generator module, and automatic control of the measurement temperature.

Specifications

Measurement value Conversion efficiency, Power generation amount, Penetration heat amount
Measurement method One dimensional heat flow input method
Module size Square 30mm×5 to 30mm t (negotiable)
Heating surface temperature Max. Max. 800 ℃
Sample temperature gradient Approx. 300 ℃ in case of thermal conductivity of Stainless steel of 30 mm t
Pressure on contact surface 2MPa
Atmosphere In inert gas
Required floor space Approx. W3000×D1000 (mm)
Weight Approx. 300 kg
Power source Power : AC 200 V, 1 phase, 4 kVA, One location PC,
Pump : AC 100 V, 1 phase, 1 kVA Outlet two locations
Grounding Resistance 100 Ω max.
one location

Constitution

  • Sample heating assembly(including frame work)  1 set
  • Programmable temperature controller  1 set
  • Measurement circuit assembly  1 set
  • Vacuum evacuation assembly  1 set
  • Data processing unit  1 set
  • Constant temperature water circulator
    (for cooling lower part heat flow measurement block)  1 set

Utility

Required floor space Approx. W 3000 × D 1000 (mm)
Weight Approx. 300 kg
Power source Power : AC 200 V, 1 phase, 4 kVA, One location
PC, Pump : AC 100 V, 1 phase, 1 kVA
Outlet two locations
Grounding Resistance 100 Ω max.
one location

Typical example of commercially available module

Power evaluation by temperature and load current

Evaluation of temperature and maximum conversion efficiency

Inquiries about this product

Related product

  1. Polymeric Thermoelectric Sheet Evaluation System ZEM-d

  2. Atmospheric Thermoelectric Module Evaluation System F-PEM

  3. Thermoelectric Conversion Efficiency Evaluation System for Small Modules Mini-PEM

  4. Seebeck Coefficient / Electric Resistance Measurement System ZEM-5 series

  5. Seebeck Coefficient / Electric Resistance Measurement System ZEM-3 series